Spur Geared Motors

Data Group: 195
SKU: 1150206
Product Number: 12GN-0348-NA2S
Category: Spur Geared Motors
HS Code: 8501.31.6000
Applications: Automatic door-lock, Projector, Hairdressing equipment.
Documents:
PDF File:
 
Untitled Document
Specifications
1.Product Description
Model Number: RoHS-compliant DC Gear Motor
2.Standard Operating Conditions
Item Content Notes
Rated Voltage 5.0V DC
Use Voltage 4.0V ~ 6.0V DC (Across Motor Terminals)
Standard Rated Load 19.6mN"m (200gf"cm)
Operating temperature Range 0 C~+50 C 20%~90% RH
Storage Temperature Range -23C+70 C (5%~90%RH) No condensation. D22 (Standard condition is 20 C temperature, and 65% relative humidity)
Motor Orientation All directions of the gear output shaft.
3. Measurement Conditions
Item Content
Motor Orientation Horizontal to the gear output shaft
Power SOurce A stable DC power source that will not lead to uncertainty in determination
determination
Standard Rated Load Unless otherwise specified, measurement shall be executed at a normal temperature, humidity, and pressure. Normal Temperature: 15C to 30C Relative Humidity: 30% to 90%
4. Electrical Characteristics
Item Content Notes
No-load Speed 62 min-130% At rated voltage, no load
Rated Load Speed 58min-130% At rated voltage with 19.6N"m load
No Load Current 120mA Max. At rated voltage with no load.
Rated Load Current 95mA30% At rated voltage with 19.6N"m load
Starting Torque [Reference Value] 294mN"m (3000g"cm) Calculated at rated voltage by 2-point method of no load and 19.6mNm load (200g"cm)
Actuation Current 750mA Max. (at 5.0V) At rated voltage (when current is 2R/3, R is the monopole resistance)
Insulation Resistance 10M W Min. At DC 100V between the motor terminal and the case.
5. Mechanical Characteristics
Item Content Notes
Thrust Play 0.02~0.35mm
Shaft Deflection 0.04mm Max. At the end of the output shaft.
Weight 8.7g [Reference]
Mechanical Noise 55 dB(A) Max. Perform Measurement
according to Measurement
Method for Mechanical Noise
Vibration 40m/s 2 Max. Perform Measurement according to Measurement Method of Vibration.
6. Endurance Characteristics
Item Conditions/Test Environment Determination Standard
Vibration Testing Acceleration of 3G on motor unit only, and limited vibration at a frequency of 5 ~ 500 Hz of in vertical direction for 30 minutes each. Must satisfy previous sections 4. and 5. of this specification.
Drop Testing Drop each of the 6 surfaces of the product in a packaged state onto a concrete surface from a height of 50cm. Must satisfy previous sections 4. and 5. of this specification.
7. Lift time testing
Item Conditions/Test Environment
Lifetime Assurance/Determination Ambient Temperature Test: After 30,000 cycles of operation, the load current should be 95mA50% of the Rated Load Current in 4. Electrical Characteristics.
High/Low Temperature Test: After 20,000 cycles of operation, the load current should be 95mA50% of the Rated Load Current in 4. Electrical Characteristics.
Lockers
 
 

©2003 KYSAN ELECTRONICS All Rights Reserved! www.kysanelectronics.com